Fanuc program protect key On the Select Screen, highlight the program you want to protect, then use the function key to enter its configuration settings (i can not remember exactly what the button says, but there are only a few options). By bmlw in forum Fanuc Replies: 2 Last Post: 10-11-2008, 08:47 PM. IndustryArena Forum > Machine Controllers Software and Solutions > Fanuc > Fanuc 21-T programs are write protected. Press the Prog soft key underneath the screen. I think it is like 8000-9000 you can not use . View Profile You should be able to input diagnostics with PWE=1 but I can confirm that if you have the memory/program protect key on, it will not let you change diagnostic parameters. 1. 07-18-2015, 01:09 AM #3 The VMC is a Harginge P3-600 with a Fanuc Oi-MC control. Hi guys, i have this old Fanuc 6M-B milling, i manage to do communication via RS232 at 2400 baud 7 bit 1bit parity even also tried 4800 and 9800 bauds i'm able to do a punch (from the machine to the pc, but it come in empty since there is no program in the machine) but unable to do a read. Select EDIT mode. I'm trying to locate the correct parameter to allow my setups to change tool offsets without the use of the key. If you're program is stored somewhere in between O8000 and O9999, parameter 3202 is used to edit-protect them ( perhaps someone changed the program number or the parameter ) 3202 bit 0 disable editing for program between O8000 and O8999. to test a theory we set that bit to 0 on the main and tried to input a program and got "write protect". so, new psu is in, and I loaded my sram in from a backup. prgrm button 3. Program protect switch: A switch located on the machine control panel that allows the operator to 14 RESET Return to stop (this key is for processing after modifying a section of the program. I would just leave the key in the machine, but I don't trust them to not accidentally change a program or something else by randomly pressing buttons. Of course I figured it out after asking twice. I got some news, so what i thought as memory protect key was a door switch bypass key (had a key icon with 1 on one side and 0 on the other). View Profile FANUC 15T Write Protect. Let's try. Regards, Bill 10-22-2013 How to lock the programs upto 8000 from editing a parameter for Fanuc system. Some of these programs are write-protected, and since they're KAREL programs I By using 3202 parameter || NE 8 for O 8000 & || NE 9 for O 9000 series. hit Delete key Does not work, nothing happens! Its almost like there exist an extra program protection parameter apart from the This turned out to be a psu that died in the ctrl cab behind the i/o board. Set Edit Key switch to I. Deutsch ; English ; Español ; 595,616 active members* 5,993 visitors online* Register for free Login. Does anybody have any idea how to disable the write-protect (no-edit) key on MORI SHEIKI SL-250 lathe with a 18i-T control? The key is a three-state switch which allows editing at 1:00 PM (but does not allow executing the program) and executing the program at 12:00 PM (but does not allow editing). well, it seems like its messed up. Therefore they If you're program is stored somewhere in between O8000 and O9999, parameter 3202 is used to edit-protect them ( perhaps someone changed the program number or the parameter ) 3202 bit 0 disable editing for program between O8000 and O8999. John Similar Threads: Protected Move Help; Newbie-Fanuc Series 180i-MB : Program is Now Write ProtectedCannot Edit! write protected dwg; write protected; Posted via Mobile Device . The program protect switch stops memory-based applications from being deleted accidentally or on purpose. Oseries: 8000 prog is parameter 389. dpelton; Sep 5, 2023; CNC Machining; Replies 0 Easiest thing to do is leave the Panel Edit key in the "On" position then remove the key. Figured by G122. When tried to change the " PARAMETER WRITE : 0 " to " PARAMETER If your cnc machine gives WRITE PROTECT alarm when try any data change or program transfer fro example from USB to memory, this video shows that how can solv Turn OFF the memory protect key switch; Press the PRGRM key to display the program screen; Key in the letter "O" and the number "1234", then press the INSERT key; Press the EOB key, then press INSERT; Yasnac LX and MX series CNC control. By cnc programmif hindi and english-~-~~-~~~-~~-~-This Video and channel https://www. cnctrainingcentre. View Profile View Forum Posts Registered Join Date Nov 2010 Fanuc Auto key: This is the key on the CNC machine (including the A16B, A17B & A20B product line) that reshapes the operation mode to automatic. this is Protect Switch Program: A switch on the machine's control panel that the operator can use to lock down the most recent program information. Press start When the button is pressed for processing, the machine will alarm. It does not come standard Password Protection RTL-J541. 7 but they might be using something else, hardware or software related. key in address O 4. Skip to content. Press the INPUT key Follow instructions for your PC or Laptop to store, edit and create programs on the ATA flash card thru the PCMCIA slot on your computer. I have a 0i that requires me to use the edit write protect key to change the tool offsets. 4. hit insert key Doesn't work, nothing happens! If a try to delete an existing program, that doesn't work either. On the select screen highlight your program and press details One other thing is you cannot create a 8000 or 9000 program in the control if they are locked. Run Program for GE Fanuc Series 160i-m from PCMCIA Card. 2 9000 prog is parameter 10. Maybe model F is a bit different. You cannot edit program without the Panel Edit key in the Edit position. 07-16-2015 R30iA Controller teachpendant program password protection procedure. ex. January 27, 2016 at 4:19 PM #1; its a paid option from FANUC. Thread: Fanuc 21-T programs are write protected. In PROG mode, press this key, the program cursor will return to the first display of the program TOP. P3211 contains the password that must be entered into 3210 in order to set P3202. The key operated switch could be any make, you can do one of three things, The "Write Protect" alarm on a FANUC 31i model B controller suggests that the All controls have a Program Protect key switch and sometimes have an All controls have a Program Protect key switch and sometimes have an Also, param 3290 (data protect) bit 7 (Key) is 1 on both the main and sub. onthebumper. Unlock Programs Fanuc Parameter, If you can't access program 9000 to 9999 on your Fanuc control then you need to know about parameter 3204. com/Fanuc Programs 9000 to 9999 can be used bt the machine control for things like tool change and touch probes. Sent from my iPhone using Tapatalk. ” Write Protect” comes out and i checked the key on There are some program number set aside by fanuc for factory use like test programs and warm up programs . Then at the write protect line, change it to true. My IndustryArena Login Remember Me? Anyone know where I can get a Program Protect key? By Billmac in forum Fanuc Replies: 11 Last Post: 04-14-2008, 05:31 PM. after rebooting then i get to the quick/nc screen, and it says the same darn thing - set the prog protect key to release. i then set the keep relays, c-data, and d-data from my paper param sheet. The MTB might not be using the fanuc-provided key signal X21. 4 You will not be able to see the value in 3211. I'm sooooooo fed up with switching the key all the time! 5. Results 1 to 5 of 5 Most machines have a physical PROGRAM PROTECT keyswitch. Key in the number 4 7. Program Protect Key: - You mentioned that the Program Protect Key is unlocked. Thread: 9000 level program Built-in Macros may be protected by a password key. I don’t quite remember if that holds true if punching in a program via RS232. maybe there is actually something wrong with the hardware that reads the prog protect key (some pcb's that are behind the control keyboards). And 3202 bit 4 protects programs in the O9000 to O9999 range. Which is why it seems odd that Spelunker had an operator punch one into the control. Check parameters P3210 and P3211. this sounds great, but the machine just keeps giving me the message to set the program protect key to the release position. ) Please help!! I am using AMS MCV-400 VMC . I have a ready RS232C Cable and PC . The program must be reset. You should be able to use the Right Arrow key to move the cursor to the WAIT-condition and then get contextual choices on the F-buttons. marun_1987; January 27, 2016 at 4:19 PM; Thread is Resolved; marun_1987. Sent from my iPhone using Tapatalk Write protecting a program is pretty simple. hit Delete key Does not work, nothing happens! Its almost like there exist an extra program protection parameter apart from the Need Help with Memory protect violation can't find where to turn this off in pendent screens Fanuc system R-J3iB. In my parameter list, it says that this value must be 00000010; according to the other post this would be for "decimal with write protect". Al_The_Man. 4 10,11,12,15 series The VMC is a Harginge P3-600 with a Fanuc Oi-MC control Problem-PROGRAM PROTECT; Anyone know where I can get a Program Protect key? Protect your G54G59; Last edited by Kurt Tedford; 05-17-2009 at 08:31 PM. 3 not changing, and then checking the wiring diagram. Reason: added control info 05-17-2009, 07:17 PM #2. If you can help . Please reply on Hello. Otherwise. MOM September 1, 2023 at 8:19 AM. Now For simplicity and 3D modelling I decided to connect with PC . Automatic mode authorizes an operator to contact and execute a part program stored in memory. i get to the quick/nc screen and in there you can 'restore' parameters, etc. key in program number 5. Fortunately in another post, someone explained the "Parameter" byte value one screen up. If you have a parameter manual for the Oi control, look under the Marco programing section, it should e listed there. Guest. 0010= 10010001 9000 Protect on 0010= 10000001 9000 Protect off. Edited once, last by RobotWizard0216 (October 15, 2018 at 10:12 PM Changed the title of the thread from “Cannot Edit Program” to “Cannot Edit Program - FANUC”. Turn the PROGRAM PROTECT KEY to the OFF position 6. The Parameter number 100 , 101 are unable to edit since it is " WRITE-PROTECTED". But the MAchine not responding. Protective Settings in Data Server: - There may be settings specific to the Data Server that prevent writing to CNC memory to protect existing programs or data. Double-check to make sure it’s fully unlocked and that the control is recognizing this status. cncgabe. So we set it back to 1 and it takes a new program fine. On the Fanuc OM series control, You need parameter #0010 bit #4 to be a 0 to edit 9000's programs and 1 to protect the programs. 08-07-2018, 01:47 IndustryArena Forum > Machine Controllers Software and Solutions > Fanuc > 9000 level program protection - 21i. edit mode 2. The robot that I'm using still has several KAREL programs from an old discontinued project that I would like to delete since I am running into some memory issues on TEMP. 12-07-2009, 03:20 PM #3. SINGL BLOCK Key: A key that makes the GE FANUC 0-C control's single block capability operational 4. the pc tells me the code has been uploaded tot the machine (i put the But when I go to load a new program it's telling me that it is code (075 Protect) has anyone ever seen this and gotten around it? I need the fix quick. Then double checked that parameter on the sub and it is 1 but still giving a "write protect". I want to edit macro variable input during write protect key is in OFF condition or removed from Fanuc Oi-TF model panel Deutsch I am not familiar with the Fanuc Oi-TF control but I do know that in other Fanuc controls you can set your data like this: (under macro-programming section). 03-27-2017, 03:50 PM #3. 3. eipep hkqcau nkqyt dpu ipmu wioyvebl rpej aflplpj ireuxinc qkcta