Digitrax ds64.
Digitrax ds64 Jan 19, 2012 · Specifically, can DS64 defined routes include turnout addresses controlled by other stationary decoders connected to the track bus but not connected via LocoNet? LocoNet is the conduit for information outside of a specific DS64, including external devices controlled by a particular DS64. Learn more on our website at digitrax. You are now ready to set up a Route. The back edge and left end have cooling slots which must remain clear. Fulgurex and NCE Switch-8: Does not work together Feb 26, 2011 · I'm using digitrax DS64 stationary decoders to drive Peco coil/solenoid switch machines (installed underneath the track). DS64 - OPSW 21 set to closed automatically reports turnout position. JMRI supports this mode in Roster-based programming, so you can treat these types of boards in much the same way as you treat mobile decoders in your locomotives - you may program them using the JMRI "Symbolic" programmers (i. No turnouts should be connected to the DS64 at this time. How to use Digitrax DS64 and BDN4 for automatic switching of turnouts. It all works great using a DT400 throttle, but I can't figure out how to make it work using the local inputs. I installed a switch in the track circuit output of the DSC51 and switched it on after the controller powered up. please try resetting the Digitrax system (DCS50/51, DB150 or DCS100/200) by closing Option Switch 39. Digitrax Big Book of DCC; Decoder Selector Support Tech Support Depot; Help Desk; Video Tutorials; Manuals & Instruction Sheets; Warranty & Repair; Throttle Conversions; CV Information and Tools; LocoNet: The Digitrax Difference; Frequently Asked Questions (FAQ) Downloads Downloads; Manuals & Instruction Sheets; Sound Depot Digitrax Products -> Stationary Decoders -> DS64 Quad Stationary Decoder This article was last updated on Sept. Jan 10, 2012 · The DS64 is a powerful stationary decoder. Stationary Decoder for use with 4 slow motion, solenoid, or bi-polar turnout machines. However, indicator lights can still wired to work with the DS64. I’ve wired a number of control panels for clubs. Apr 17, 2021 · Check the Power supply. Coastal DCC Ltd Registered Offices: Ipswich Model Railway Centre, 48-52 Tomline Road, Ipswich, IP3 8DB Digitrax for sale Digitrax sdck signal: 11. Sep 22, 2023 · If you have tried resetting the DS64 by closing Option Switch 7 and that has not worked for you, please try resetting the Digitrax system (DCS50/51, DB150 or DCS100/200) by closing Option Switch 39. My problem is that the DS64 does not seem to be generating any messages for the sensors. Feb 22, 2009 · Digitrax DS64. Mar 23, 2017 · I am using DigiTrax DS64's to address the Kato turnouts. KB805 DS64 - Setting Board ID for Additional DS64s. My question is: Do I need to attach all four wires or just one set of wires? The PL-10 is a coil-type switch machine with double solenoids. General LocoNet system input sensors. com or via the enquiries form on our Contact Us page. I know Digitrax has the DS64 which controls four machines, can use its own power supply and Aug 19, 2024 · That is a stationary decoder. The return connection of each push button is made to "+COM. Up to 4 Kato Unitrack switches (such as the Unitrack double crossover) can be operated a on a single DS64 output. Find instruction sheets, specifications, case studies, and 69 articles on topics such as powering, programming, and connecting turnout machines. 12 £ | Gauge model railway: 516. 7K views 10 replies 4 participants last post by yak-54 Mar 17, 2013 Oct 8, 2020 · A quick demo for how to use a Digitrax DS64 Quad Stationary Decoders to control turnouts on the Mon-Yough Valley mainline at McKeesport Model Railroad Club The sensor inputs of the first DS64 and the first sensor input of the second DS64 are used for the route push-buttons for panel route control. The literature says that you can only use May 24, 2011 · At the factory, your DS64 was set to control solenoid type turnout machines that use a single pulse output for operation. Using track power can induce problems as power drops can occur the farther you move from feeders. The LocoNet cable is used only for LocoNet commands. What about other DCC systems?A: Yes, Digitrax detection and signaling will work with any DCC system. Q: Is it possible to use Digitrax equipment to wire the Kato N-Scale Automatic Track Crossing? If so, how do I do it? A: The answer is a probable "No", but there may be a workaround. I successfully wired three DS64's together with Cascading Routes and such. DS64 Quad Stationary Decoder. Learn how to use and troubleshoot the DS64, a device that allows you to control turnouts directly through DCC. In the DS64 picture – it shows 2 Digitrax DS64’s, which control the switch/point turnouts. Configure Digitrax DS64 The JMRI DS64 Configuration tool lets you configure the internal options of a Digitrax DS64 Stationary Decoder directly from your computer running JMRI. For example, you can run 2 Tortoise or Switchmaster machines on a single DS64 output. Even Kato's SwitchKat does not do that. The DS64 board ID is "1" so I set the sensors up in the sensor table as LS1, LS3, and LS5. Easily hook up external DC power either by a PS-14 connector or to a terminal strip. Leave the jumper block on both pins of JMP1 on the MRD8. KB520 General DCC Power Supply Information. DS 64 Power. BD4 lets you know which detection sections of your layout are occupied by locos and rolling stock. After that, it got so hot it melted the platic over the ventillation grill and all four of the outputs showed about 4 Nov 23, 2015 · This is also documented in the file section of the Digitrax group Randy referred to. 2. Jan 10, 2012 We have 1 Digitrax DS64 manual available for free PDF download: Manual Digitrax DS64 Manual (21 pages) Stationary Decoder for use with 4 slow motion, solenoid, or bi-polar turnout machines DS64: Figure 3 shows one Azatax MRD8 octal infrared train detector connected to the eight inputs of a Digitrax™ DS64 stationary decoder. 0 bids · Time left 5d 3h +$15. May 24, 2011 · Digitrax Products -> Stationary Decoders -> DS64 Quad Stationary Decoder KB808: DS64 - Choose either solenoid or slow motion turnouts for a single DS64 This article was last updated on May 24, 2011, 7:07 p. May 24, 2011 · Digitrax Products -> Stationary Decoders -> DS64 Quad Stationary Decoder KB812: DS64 - Diagram This article was last updated on May 24, 2011, 6:41 p. Rick Allen’s Railroad with Berrett Hill Touch Toggles, Digitrax DS64 and Train Buddy custom designed electronics for massive staging Ok, so I don’t expect every railroad to use this technique to run their staging yard, this railroad is SO big and expects to have SO many locos on the track at the same time that it makes sense to power down Jul 6, 2010 · I am using Tortoise switches that are controlled with DS64s. Subscribe To The Digitrax YouTube page! Join The Digitrax User Group. You will need to set the DS64's board ID if you are planning to use the DS64's 8 inputs with a computer, system throttle, or other smart device on your layout that needs to know when a turnout has been May 24, 2011 · Digitrax Products -> Stationary Decoders -> DS64 Quad Stationary Decoder KB802: DS64 - Route Table This article was last updated on May 24, 2011, 7:21 p. Mar 28, 2017 · Afterwards it wants a cv value. Without any changes being made to the system and without any warning the #3 output refused to respond to commands when attempting to activate the switch attached to it. It seems to me that there should not be a problem, but one fellow told me not to do this. Thanks! Jan 27, 2023 · I have spent the last week trying to successfully wire and program my control for 16 Kato turnouts. Note: Multiple turnout machines can be operated on a single DS64 output. This affordable, easy to install decoder will add another dimension to your operations. The board addresses are set to 1 to 4 while the switch addresses are programmed in sequence from 1 to 16. Local turnout control. com. The DS54 has been discontinued by Digitrax. To reset DCS52 Oct 29, 2014 · 1. Welcome to the Digitrax Tech Support Depot! Find Support by Category. The startup delay tells the DS64 to wait for a certain amount of time after the layout is powered up before ‘waking up’. Find many great new & used options and get the best deals for Digitrax DS64 Stationary Decoder For Use W/ 4 Slow Motion T/O Machines at the best online prices at eBay! Free shipping for many products! Digitrax Products -> Stationary Decoders -> DS64 Quad Stationary Decoder Digitrax Products -> Detection and Signaling -> BD4-Quad Block Detector KB391: DS64 - Sensor Activated RR Crossing Lights with the addition of a BD4 May 24, 2011 · The DS64 has a route table that can hold up to 8 individual routes that consist of a "Top" address and 7 additional turnout addresses and their positions. The DS64 must be powered via the rear modular connector (12-14 volts AC or DC) OR via the AUX power 12-16 volts DC using AX1(-) and AX2(+) on the circuit board at the front of the unit. May 24, 2011 · Note: The DS64 is configured for either for solenoid turnouts (the default setting) OR slow motion turnouts. Unpack the DS64 and mount it in a location with easy access to the turnouts you want to control. 11 £ | Model railway digitrax: 37. 95 delivery. May 24, 2011 · To set up your DS64 to operate stall motor type turnouts: 1. And on the Digitrax site it appears that half the people had issues the could not be resolved but the other half did not. You ideally want 1 power supply for each DS64. Sep 22, 2014 · Hi Everyone - Please take a look at this YouTube video I made. 8cm (width) x 3. The numbers 50 & 51 on the labels refer to their board ID address, and the numbers 101-104 & 105-108 is the address of each point/switch on the track, and as I am only using 3 points and a double slip, I am only using address 101 to 105. The back edge has two LocoNet connectors and a barrel style power supply connector. The DS64 Stationary Decoder allows you to install and operate your turnouts directly through any DCC system that has turnout control. Dec 16, 2018 · I am setting up 4 Digitrax DS64 on my layout to run a bunch of Tortoise switch machines. i would preffer to not have the clank but since i decided against stall motor machines i have to have it. Digitrax DS64 DCC Stationary Decoder, 4 Turnouts . | Print Article | Leave Feedback When you program the DS64, you must program all four outputs, even if they are not connected to anything. ” If you have reconfigured your DS64 for stall motor type turnouts, the DS64 can be reconfigured back to solenoid type turnout motors. How to use Lamp Mode on the DS74 - Learn how to use Lamp Mode on the new DS74. Leave this field empty if you're human: Payment Options. The DS64 "latches" in either position so the push button fascia switch does not need to remain depressed. Zephyr DCS51 to DS64 via loconet, Kato Switch factory wires to 1R/1G ports of the DS64. On the DS64’s control panel, press and hold the ID button down for 3 seconds until the green LED slowly blinks on and off. We will generate one route for each track. The DS64 works with a wide selection of hardware, such as solenoids to slow motion motors. Opens in a new window or tab. This allows for adequate current for the switches. However, I am not getting rid of all the track I already purchased. OPSw 11 enables the local inputs to trigger the routes stored in the DS64. Turns out the problem was that I connected and powered up the DS64 to the Tortise turnouts BEFORE I set SW01="c" for stall type turnouts. Cascaded route & turnout control. Mar 6, 2020 · Connecting a Digitrax DS64 to control both a Tortoise and a Fulgurex via DCC:. Note: The wires that connect the BD1 to the rails and rail power source are characterized as two heavy, uninsulated, and polarity neutral wires. 4. Make sure the momentary-on push buttons are wired as shown in Fig. However, I see now that Digitrax has replaced them with DS-74s. Brand: Digitrax. Allan Gartner photo. Is there a way to stop all the DS64 switch decoders from throwing switches once the power is switched on? Almost every time I turn the layout on the switches throw opposite. Jul 21, 2021 · Differences in the DS74 from the DS64: Up to date and compact LocoNet design with customer IPL/firmware field update capability using DigiIPLII. Apr 23, 2013 · The DS64's approximate size: 12cm (length) x 8. Your DS64 experience might be related to that issue. Press and hold down the STAT button on your DS64 until the green LED begins to blink quickly. 4 outputs for turnouts. Mar 6, 2020 · Connecting a Digitrax DS64 to control both a Tortoise and a Fulgurex via DCC: According to Digitrax tech note KB273, this configuration cannot be used as the Fulgurex takes “about 400 mA” when running, which exceeds the specifications of the Digitrax DS64 as well as ones of the NCE Switch-8. 8 internal LocoNet integrated System routes, that can be conveniently Can a DS64 be powered from the LocoNet RailSync lines? No. DS64 media converter pdf manual download. Block occupancy detectors, using Digitrax BD1 detector modules. Digitrax DB150 Command Station/Booster Power On LED Diagnostic BlinkingSteady on = DB150 is operating as a Command Station/Booster 1/2 sec on / 1/2 sec off = DB150 is operating as a Booster only 1 sec on / 1 sec off = DB150 is in Option (OP) mode, the Option switch is in the OPTN position 2 sec on / 2 sec off = DB150 is in Sleep mode, the Option Oct 11, 2016 · Looking for a straight answer on DS64 power sourse options along with Loconet. Digitrax PM4, BDL168, SE8c and DS64 boards use a special messaging protocol to program their Op Switches. Handles Kato Crossover switching with no issues. How to use Slow Motion Turnouts on the DS74 - Learn how to use Slow Motion Turnouts on the new DS74. They are horrible. In my case, I have one supply for my PM42, another for my DS64’s, and a third for my UP5’s. Note: If you find that your turnout is operating “backwards” simply switch the + & - wire connections to achieve correct operation. m. Can run 4 turnouts from The DS64 Stationary Decoder allows you to install and operate your turnouts directly through any DCC system that has turnout control. It seems that folks with the MRC throttle all had troubles similar to mine. May 24, 2011 · Digitrax Products -> Stationary Decoders -> DS64 Quad Stationary Decoder This article was last updated on May 24, 2011, 7:30 p. Digitrax-DS64-Manual-2014. The BD1 is also compatible, for the same purpose, with the DS64 and SE8c. Jan 16, 2012 · The momentary push buttons are connected to the DS64 inputs marked S1, S2, S3 and S4. Jan 20, 2012 · I am trying to wire my new layout (N gauge) using the DS 64 with Peco switch machine PL10. Here are the questions. Digitrax DS74 Mar 12, 2024 · Summary: The DS64 Stationary Decoder allows operation of turnouts directly through any DCC system that has turnout control. Apr 12, 2012 · Additionally, DS64 Stationary Decoders are designed to allow up to 8 Routes to be programmed internally into them. The route programming is done with the DS64 connected to an active Digitrax command station by a Loconet cable. Apr 20, 2020 · Digitrax recommended a DS64 to take the sensor inputs. the Roster). To open this tool select "Configure DS64" from the LocoNet menu for the connection this DS64 is attached to. Dec 20, 2017 · My question arises from having 4 turnouts in my layout plan, and other than purchasing a Digitrax DS64 or 2 DS52's, I don't see any other way. Aug 7, 2014 · How do I connect a BD4 to a DS64? The BD4 is a block occupancy detection device designed as an add-on device that can take advantage of the LocoNet hosting capability of the DS64 stationary decoder. 13, 2011, 6:43 p. | Print Article | Leave Feedback Jan 25, 2016 · The power supply used must provide enough current if it is powering more than one DS64. For Digitrax accessories, the recommendation is to power each type of device with it’s own supply. Electronics and DCC. I thought by wi Digitrax available from Coastal DCC. (3) DS64s were purchased new from Dallas Model Works in 2022 before their supply ran out. 5cm (height) 4. as i understand it you can also add switches so it can use both the dcc signal and the push button. My plan was to just parallel the wires of the Kato control switches and connect them to the DS64. It is connected in this way: Apr 15, 2011 · The DS64 has a latching type of operation in that a pulse of voltage (the switch being depressed) causes the DS64 to toggle (flip) between two states. or The Loconet cables could be causing problems. If you are using LocoNet, connect one end of an RJ12 cable to either of the DS64’s LocoNet sockets and connect the other end of the cable to your existing LocoNet network. the clank is a by-product of using those coils. Tortoise or other slow motion swith machines can be wired in two different ways. | Print Article | Leave Feedback Feb 3, 2013 · Digitrax DS 64 Jump to Latest 2. Find out more about the DS74 on digitrax. Control panels stick out into aisles and therefore need to be rugged. From solenoid turnout machines to slow motion motors, the DS64 hasn’t met a turnout it doesn’t like. 1 above. According to Digitrax tech note KB273, this configuration cannot be used as the Fulgurex takes “about 400 mA” when running, which exceeds the specifications of the Digitrax DS64 as well as ones of the NCE Switch-8. All plug-in connections. Digitrax Stationary Decoders Specification Sheet DS64 Quad Stationary Decoder Turnout Machine Type Control 4 Slow motion turnout machines OR Control 4 solenoid type turnout machines Switch Interface Screw terminals Turnout Addresses 4 Control of second turnout per output Yes , (Up to 4 if switches are Kato Unitrack) Unpack the DS64 and mount it in a location with easy access to the turnouts you want to control. Only one DS64 can be powered per PS14. I am about 99% sure I have a faulty DS64 but any advice you can give me is appreciated. Jul 2, 2016 · Unfortunately Decoder Pro does not yet have any provision to program routes on a DS64. e. Sponsored. 1. The PL10 has four wires to be attached. | Print Article | Leave Feedback KB805 DS64 - Setting Board ID for Additional DS64s. DS64 #3 and 4 are used only for turnout setting. The DS64 requires 300mA for proper operation. May 24, 2011 · OpSw 08 startup delay and power management of DS64 OpSw 08 doubles the DS64’s startup delay. | Print Article | Leave Feedback Digitrax DS74 Quad Switch Stationary Decoder Replaces DS64 All Scales. When the DS64 tries to operate Fulgurex motor, the excess current draw appears to be a short circuit and the DS64 shuts down to protect itself. I find conflicting info in the Digitrax tech notes for the DS64 concerning use of Loconet with the various optins for applying power to the DS64. Configurable for Capacitive Discharge with balky solenoids. There are many transformers and power packs that can supply input power for Digitrax boosters & command stations. When used in conjunction with the DS64 or SE8C the BD4 provides LocoNet detection for 4 occupancy detection sections. This happens at most startups but sometimes only one DS64 throws while my other one stays. For example two DS64s will require 600mA. If a mistake is made on one, it won't effect the others. In this case the two states are the direction of the DC voltage being sent to the tortoise. KB673 DS64 Stationary Decoder-Power & RailSync. Aug 26, 2012 · Anyone using the NCE Switch-Kat or the Digitrax DS-64 with Kato switches? I figured out how to use Digitrax DS64 to throw points on the Kato #6 Switches. Crew; Posts: 1434; Respect: +483; Re: NCE - throwing Kato unitrack switches Jul 20, 2021 · Digitrax Stationary Decoders Specification Sheet DS74 Quad Stationary Decoder Turnout Machine Type Control 4 Slow motion turnout machines OR Control 4 solenoid type turnout machines OR Control 8 Lamps Switch Interface Pull Out Screw terminals Turnout Addresses 4 Control of second turnout per output Yes, (Up to 4 if switches are Kato Unitrack) May 24, 2011 · Note: Multiple turnout machines of the same type can be operated on a single DS64 output. Nov 24, 2021 · The new Digitrax DS74 can control up to four turnouts or eight LEDs. Feedback of turnout position, including "out of position" during changes. I am also going to email Digitrax support to see if they have any suggestions. On the DS64 press and hold the OPS button down for about 3 seconds until the red OPS LED and green ID LED begin to blink alternately. For larger routes, you can set up Cascading Routes by using multiple DS64s. I know this is probably way more trouble than what it's worth. May 24, 2011 · Digitrax Products -> Stationary Decoders -> DS64 Quad Stationary Decoder; KB813: DS64 - Connecting to LocoNet. Sensors can also be used with the DS64 to activate routes . Peco u will have to change it through the ds64 , the ds64 will operate either ,if u have any problems call digitrax they are great with customer service The Digitrax manual has next to no info on how to wire the inputs for the DS64 stationary decoder. ? Slow Motion Machines. The routes are programmed one at a time using the button on the DS64 and a throttle. I have no personal experience with it, but if it is DCC-compliant (not reason to think otherwise), it should work equally well on any DCC-compliant DCC system. The DS64 works with a wide selection of hardware. I joined both the Digitrax and the MRC yahoo groups and read through everything that had to do with DS64 decoders. Dec 15, 2010 · "Multiple turnout machines can be operated on a single DS64 output. When using more than one DS64 in a DCC environment, you must assign a Board ID to each additional DS64 so that each one has a unique Board ID. 00. 72 £ Jan 25, 2016 · Can a DS64 be powered from the LocoNet RailSync lines? No. my question is is there a way to add led lights to so i can just look at the panel to check the direction of the switch. Are any of you successfully using DS64 stationary decoders to control Tortises? I purchased my first DS64, hooked it up and it threw the first turnout a few times. Jan 25, 2016 · DS64. $50. If using Trk A and Trk B to power the DS64, no LocoNet connection is necessary. I read where the DS64 is a nightmare in that it throws the switches upon powering up not sure about the DS52? Digitrax devices which make use of "Board ID" numbers, but which cannot be programatically configured, include: Digitrax DS64; Digitrax BDL16, BDL162, and BDL168; Digitrax PM4, PM42; Digitrax SE8C; Digitrax BXPA1; Digitrax BXP88; For these devices, JMRI cannot configure the Board ID number under JMRI's control without user intervention. " so this i'm happy about thanks on input clarification. I have the buttons wired to A1 and A2 on the DS64, with the photo electric sensor wired to A3. As the train approaches the gates, the BD4 will send a message to the DS64, which will operate the solenoid mechanism. . 4" (height) The front edge of the DS64 needs clearance for wires to be attached. 2. Only one type of turnout motor can be used on any particular DS64. Please refer to the DS64 manual and other Tech Support Depot articles for additional information on programming Routes. I'm not sure whether it's a DS64 issue or a Loconet issueBut here goes: I'm running a Radio Super Cheif system with 9 UP5s, 1 UP91, 9 DS64s, 1 UT400, 1 UT400R and 1 UT4R. I enter "1" for thrown. It is about 1/3 the size of its predecessor, the DS64. I am willing to try anything to get this to work before I send it back. Some additional information for the DS64. A1 will trigger route1, S1 will trigger route 2, and so forth. Connect the DS64’s ‘TRKA’ and ‘TRKB’ terminals to your track. May 24, 2011 · Note: If your route includes switch addresses from more than one DS64, they must both be connected to LocoNet or the route will not run. Differences in the DS74 from the DS64: Up to date and compact LocoNet design with customer IPL/firmware field update capability using DigiIPLII. It is also possible for the DS64 to get it's The DS64 Stationary Decoder allows you to install and operate your turnouts directly through any DCC system that has turnout control. Features: Quad switch decoder for Solenoid or Slow-motion turnouts. Feb 19, 2017 · The Digitrax DS64 can be configured to operate the Kato turnouts. On some rare occasions they don't The DS64 Stationary Decoder allows you to install and operate your turnouts directly through any DCC system that has turnout control. Model Railroader. He thought that there might be a conflict between the outputs of the Kato control switches and the DS64. | Print Article | Leave Feedback This example is a small yard with a crossing signal at its entrance. Over this past weekend I had a new Digitrax DS64 that apparently decided to become a plastic paperweight. Use PS14 (external power supply) to power the DS64 not track power. Important Note: You cannot cascade routes within the same DS64 route table. ? I have a large layout that is powered by Digitrax system and am attempting to set up 2 DS64's to control turnouts and set up routes through the yard. Turnouts can be either connected or not. ? Operates four turnouts. They do not keep the points tight against the rails Jun 15, 2009 · The PS14 is a 300ma, 14 Volt power supply for powering Digitrax accessories like the UP5, BDL168, DS64, SE8C, LNRP, UR90, UR91 UR92 and others Universal AC input 95-240V 50/60Hz US 2 prong plug, in sideways orientation Jul 3, 2018 · I use the ds64 with tortoise switch motors and the NCE PC it works great. Pre-Owned. Jan 13, 2012 · Why does the DS64 generate multiple output pulses for a single command? I get between 2 and 5 pulses over a period of about 2 seconds. This caused the DS64 to operate the Tortises as double solenoid type machines, which is the default, and which apparently will blow out all the outputs on the DS64 as soon as it powers up with Tortises connected. To reset DCS52, DCS210 or DCS240 close Option Switch 40. Begin with your DS64 powered up. System Power On/Off & Run/Stop inputs. Stationary Decoders -> Quad Stationary Decoder (DS64) The DS64 Stationary Decoder allows you to install and operate your turnouts directly through any DCC system that has turnout control. Works with compatible LocoNet Systems. cctuna February 22, 2009, 1:14am 1. Option Switch 01 determines the type of turnouts that you can operate, static or pulse. : 1) There appears to be 5 ADDRESSES programmable in the DS64. I started out with (8) Digitrax DS64 quad decoders, which are well documented to work with my equipment. This I do for all the 3 remaining turnouts controlled by the DS64. Here, a momentary button is connected to operate Turnout 1 with a connection between S1 and +COM May 10, 2016 · NOTE: During this procedure the DS64 must be connected to an active LocoNet with an active command station. Configurable for on/off control of 8 layout lights. To program the DS64 Route Number, use your DCC throttle in Switch mode to select a Switch Address from 1 through 8 and issue a Closed or Thrown command. Find Support by Product. This lets the DS64 know which of the 8 available routes KB386 DS64 - Kato Unitrack N-Scale Automatic Crossing Gate & Three Color Signals. Feb 26, 2011 · I'm using digitrax DS64 stationary decoders to drive Peco coil/solenoid switch machines (installed underneath the track). You can also connect switches and occupancy detectors. From Solenoid turnout machines to slow motion motors, this affordable, easy to install decoder will add another dimension to your operations. Why when all it supports are 4 turnouts? 2) According to the Digitrax video as one adds more turnouts the led flashes faster each time. I am VERY unhappy about the way that the solenoids work on all of my Bachmann turnouts. DS64 is set up by setting Option Switches (OpSw)This is how to set option switches on the DS64:1. Mar 19, 2012 · Hi OnTheRightTrack, The DS64 has two loconet sockets in the back, so you just plug in the loconet cable into one then another cable from that one to the next DS64 and so on, then you have to set the id of each DS64, Address, etc plus the output switch numbers etc. This can be done with DS64 and BD4. I want to power them from an external power supply, not from the track. 7 out of 5 stars 25 ratings | Search this page . Connect the DS64 +COM terminal to the C14 or C58 terminal of the MRD8 detector. Switch commands will be sent through the rails to the DS64. I seem to be having problems operating atlas switches via a Digitrax DS64. Aug 8, 2014 · Is this possible using the DS64 inputs or the Tortoise connections? The DS64 does not have separate connections for indicator lights for trackside or for a control panel. 75" (length) x 3. Sep 13, 2011 · Using the gate in a DCC environment will require the operation of the gate mechanism, and it will require train detection so that the gates work when a train is approaching. See Article on Cascading Routes. I plan to use routes with some stored in the command station (DCS200) with others as local routes stored in the DS64 where some local routes may involved turnouts Jan 16, 2012 · We have determined that the Fulgurex motor draws too much current for the DS64. i contacted digitrax and they KB503 DB150 Power On LED Diagnostic Indications. For example, you can run 2 Peco or Atlas Snap Switches on a single DS64 output. If you are using solenoid type turnouts, you can install the DS64 “out of the box. My troubleshooting found there was constant voltage on the Jun 28, 2015 · Digitrax technical support responded telling me that this is normal if the DS64 is powered at the same time that the DSC51 is powered. Signaling system control messages The BD1 is also compatible, for the same purpose, with the DS64 and SE8c. Feb 5, 2020 · Can the DS64 be connected to the rails to receive a DCC signal from any controller? I am planning to get the Digitrax DCS210 Advanced Command Station and use LocoNet once I have track down on a larger more permanent layout. Apr 3, 2014 · Set DS64 OptionSwitches 11 and 15 to 'c' closed to enable route commands from local inputs. Normally, I would just go with the upgraded product, but I am reading conflicting information about the new auxiliary stationary decoder. 5" (width) x 1. Local route control. So easy. It is recommended to power each DS64 individually. Nov 18, 2019 · Unfortunately Decoder Pro does not yet have any provision to program routes on a DS64. DS64 Features: ?Easy to install and operate. In this episode of It's My Railroad we take a look at how we automated two turnouts on the Brown Smith Railroad. View and Download Digitrax DS64 manual online. Digitrax Owners Manual: DS64 Accessory Decoder If you have any questions or feedback regarding this advice, please feel free to contact us at salesuk@dccconcepts. Most regular DC train control packs do not have enough power to supply the full power potential of the a 5 or 8 amp booster, since they were designed to only run 1 locomotive in a blocked system. Digitrax DS64 Quad Switch Stationary Decoder. Track power (Trk A and Trk B), Auxiliary power (AX1(-) and AX2(+)) and power through the rear modular power connector. I want to use several DS64’s to control turn outs (PECO). depending on the switch motors u use slow motion or snap i. QUICK LINKS. The DS64 works best with the DC powers from Digitrax. Digitrax sells PS14 power supplies for this purpose that are rated at 14 volts at 300ma. I am having issues with a Digitrax DS64. The use of Third-Party Software LocoNet Checker allows for quick and easy programming of Routes in your DS64. Thrown (factory default) the DS64’s startup delay is 65 milliseconds times the Switch Address programmed for Output 1. The following diagrams indicated how to connect the BD1 to the rails, rail power source, and the Digitrax DS54, DS64 and SE8c. Currently unavailable. Can support on expansion header up to 4 DSXCP1 fascia SW control panels with SW direction indicator LEDs. KB594 Is Digitrax signaling and detection equipment compatable with other DCC systems? Q: I have a Lenz Set 100 and was wondering if I can use my DCC system and use the Digitrax signaling and detection components. Plug and play wire connectorization. There are three different ways to power the DS64. I currently have a Digitrax DS52 controlling two turnouts with Tortoises, but I have more I need to control, and I also want to get out of using track power as I’m planning to use more locos with sound. Can a DS64 be powered from the LocoNet RailSync lines? No. Published sources describe the Fulgurex motor as needing 400 Ma for operation, which is well beyond the capacity of the DS64. This indicates that the DS64 is ready to accept address programming for the Outputs. I am hoping some of you with experience using both DS-64s and DS-74s can answer my May 26, 2016 · Hello i just hooked two Digitrax DS 64's to my NCE Power Cab also jmri and they work perfectly. Mar 31, 2023 · Jeff, my research on the DS-64 indicates an extremely versatile decoder. Aug 19, 2024 · That is a stationary decoder. Logged w neal. The PS14 power supply can be used with Auxiliary or the rear modular power connector. oh well. Mar 6, 2018 · I’m looking for a DCC stationary decoder to control several turnouts (using Tortoise machines). This indicates How to program the Digitrax DS64 for slow motion switch machines such as the Tortoise machines on your DCC layout. We made good use of the Digitrax DS64 staion Dec 13, 2021 · DS64 - all outputs must be the same type of motor (selenoid or Slo–mo) 4: DS54 - an external switch must be wired for turnout position reporting to computer. Each output capable of handling 4 Kato turnouts. Jun 29, 2022 · I have several DS-64s I am in the process of installing on my layout and I was going to purchase some more. 7 4. I also have a programming track with the latest JMRI software and USB Loconet Interface. Also, we show how to wire the input and o May 26, 2007 · Thanks for the suggestions. Register for Newsletters! Register. My question is KB673 DS64 Stationary Decoder-Power & RailSync. tple ccyvo ciuyq wflh tqot sifa dcypcwk tnfba mqmyrfh wmhgr